Fire Protection for Warehouses and Manufacturing Facilities in Northern Virginia, DC and Maryland

In a warehouse or plant, fire extinguishers are an OSHA matter as much as a fire code one. Inspectors from both look for the same things: units mounted and reachable, a current tag, a monthly check on record and employees who have been trained to use them.

Homer Fire Protection services extinguishers and emergency lighting for warehouses, distribution centers, light manufacturing, print and fabrication shops, breweries and contractor yards across Northern Virginia, DC and Maryland, and trains crews on site.

Lets talk now?

Homer Fire Protection serves warehouses, distribution centers and manufacturing plants across Northern Virginia, Washington DC and Maryland. Call, email or use the form to book an inspection or request a quote.

Or use this form.

What OSHA and the fire code require

  • OSHA 29 CFR 1910.157. Extinguishers mounted, identified and accessible; a visual inspection monthly; maintenance annually; and training for employees when hired and every year after.
  • Coverage matched to the hazard. Storage and production areas are ordinary or extra hazard, which shortens spacing and raises the required rating compared with office space (NFPA 10).
  • Special hazards. Combustible metals need Class D agents; flammable liquid storage and dispensing need high B ratings or wheeled units; battery charging and electrical rooms need non-conductive agents.
  • Hot work. Welding and cutting require a charged extinguisher at the work and, in most cases, a fire watch.
  • Lit exit routes. Exit signs and emergency lighting along every route out of the racking and production floor, tested monthly and for 90 minutes annually (NFPA 101; OSHA 1910.37).

Where facilities get cited

  • Extinguishers blocked by pallets or hanging on columns that have since been racked in.
  • Forklift damage: bent handles, crushed hoses, units knocked off brackets and put back.
  • No training records, or training that covered the day shift only.
  • Racking changes that turned a 60-foot walk into a 150-foot one.
  • Emergency lights mounted at 25 feet that no one has tested since the building was fitted out.

What we do for industrial facilities

  • A coverage survey after any racking or layout change, with a marked-up plan.
  • Annual maintenance, six-year service and hydrostatic testing for ABC, CO2, Class D and wheeled units.
  • Optional monthly inspection service where staff time is short.
  • Emergency and exit light testing, including high-bay fixtures.
  • Hands-on OSHA extinguisher training for every shift, plus online Training Academy seats for new hires, with records for your safety file.

Industrial areas we cover

Most of our industrial customers are within a short drive of our Alexandria base: Springfield, Newington and Lorton along the I-95 corridor, the Eisenhower Valley, Merrifield, Chantilly and the Dulles corridor, and across the river into DC and Maryland. If you have just taken a new space, we can survey it before you rack it, which is far cheaper than relocating extinguishers afterward.

Schedule A Free Consultation Today

Not sure your facility would pass a fire marshal inspection today? Book a free walk-through. We will check every extinguisher, system tag and exit light, and tell you exactly what needs fixing, with no obligation.

Warehouse and Plant FAQs

Yes, where the employer provides extinguishers for employees to use. Training is required when an employee is first assigned and at least once a year after that (29 CFR 1910.157).

For ordinary combustibles the maximum travel distance is 75 feet, and each extinguisher covers a limited floor area that shrinks as the hazard rises. Flammable liquid areas need them within 30 to 50 feet.

Your own staff. It is a quick visual check that should be initialled on the tag or logged. The annual maintenance must be done by a certified technician.

Yes. Tell us what metals or liquids you handle and we will confirm the agent and size on a site visit.