Fire Protection for Property Managers in Northern Virginia, DC and Maryland
A property manager rarely has one fire inspection to worry about. There is a portfolio of buildings in two or three jurisdictions, each with a different fire marshal, a different month when the extinguisher tags expire, and tenants who assume the common areas are someone else’s problem.
Homer Fire Protection services extinguishers and emergency lighting across office buildings, shopping centers, condominiums, HOAs and apartment communities from Alexandria to Tysons, Reston, Arlington, DC and Bethesda. We put every building on one schedule and keep the records where you and your engineers can reach them.
Lets talk now?
Homer Fire Protection serves office buildings, shopping centers, condominiums and apartment communities across Northern Virginia, Washington DC and Maryland. Call, email or use the form to book an inspection or request a quote.
- 703-646-8290
- [email protected]
Or use this form.
What you are responsible for as owner or manager
- Extinguishers in common areas, corridors, mechanical and electrical rooms, trash rooms and parking garages. Annual maintenance by a certified technician, a monthly visual check, six-year internal maintenance and 12-year hydrostatic testing for dry chemical units (NFPA 10).
- Travel distance. No more than 75 feet to an extinguisher in ordinary office and residential common areas; less where flammable liquids are stored.
- Emergency and exit lighting on every exit path: stairwells, corridors, lobbies and garages. A 30-second test monthly and a 90-minute test annually, with written records (NFPA 101).
- Tenant spaces follow the lease. The fire code holds the owner and the occupant both responsible, so the lease should say who maintains extinguishers inside each suite. We can service tenant suites on the same visit and invoice them separately.
- Tenant kitchens and food-service tenants need a hood suppression inspection every six months. A lapsed tag in a restaurant bay is a risk to the whole building.
What goes wrong in managed buildings
- Tags expire building by building because each property was first serviced in a different month by a different vendor.
- Extinguishers go missing from garages and stairwells and nobody notices until the fire marshal walks the building.
- Emergency light batteries fail the 90-minute test. Most units pass the push-button check and then die after ten minutes. The annual test is the one that finds them.
- A tenant build-out moves walls, and the extinguisher that used to be 60 feet away is now 110. Coverage has to be re-checked after every reconfiguration.
- No record of the monthly checks, which is the first thing an inspector asks for.
What we do for property managers
- Portfolio scheduling: all buildings serviced in one annual cycle, with the six-year and 12-year work forecast in advance so it can be budgeted.
- A per-building inspection report after every visit, with deficiencies listed and priced, available through our customer portal.
- Emergency and exit light testing, battery and fixture replacement.
- Extinguisher replacement, recharge and cabinet repair after a discharge, theft or vandalism.
- Fire extinguisher training for engineering and front-desk staff, on site or through our online Training Academy.
One portfolio, several fire marshals
Buildings in Fairfax County answer to the Fairfax County Office of the Fire Marshal, Arlington properties to the Arlington County Fire Prevention Office, Alexandria properties to the city’s Fire Prevention and Life Safety section, DC buildings to DC Fire and EMS, and Bethesda properties to Montgomery County Fire Code Compliance. Virginia and DC enforce codes based on the International Fire Code and Maryland enforces the State Fire Prevention Code, but all three point to the same NFPA standards for extinguishers and emergency lighting. That means one inspection method works across your whole portfolio, and our reports are written to be handed to any of these offices.
Schedule A Free Consultation Today
Not sure your building would pass a fire marshal inspection today? Book a free walk-through. We will check every extinguisher, system tag and exit light, and tell you exactly what needs fixing, with no obligation.
Property Manager FAQs
It depends on the lease. The fire code holds both the owner and the occupant responsible for keeping extinguishers maintained, so most leases assign common areas to the landlord and the suite to the tenant. If the lease is silent, the fire marshal will usually cite the owner.
A quick visual check every month, which building staff can do, and maintenance by a certified technician once a year. Dry chemical extinguishers also need internal maintenance every six years and a hydrostatic test every twelve.
Yes, in most multifamily buildings with shared corridors, garages, mechanical rooms or amenity spaces. The association is responsible for them as the owner of the common elements.
Yes. We set one schedule for the portfolio, report on each building separately, and can split invoices by property or tenant.